19
^PV (Reflected (reverse) Power, GET only)
GET format: ^PV;
RESPONSE format: ^PVnnnn; where nnnn is the reflected power from the antenna connector, in tenths
of watts. For example, ^PV0034; indicates a reflected power of 3.4 watts.
^RS (Reset, SET only)
SET format: ^RS;
^RS; resets the microcontroller. This is equivalent to removing the power plug and plugging it back in
again.
^RV (Firmware Revision, GET only)
GET format: ^RV;
RESPONSE format: ^RVnn.nn;